ACTIDATA-MIB :: relay1

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ACTIDATA-MIB › relay1

relay1

Module: ACTIDATA-MIB

OID (symbolic): ACTIDATA-MIB::relay1

OID (numeric): 1.3.6.1.4.1.37758.1.20

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Relay 1 output

What is relay1?

Controls or reports the state of relay 1 output, with values ranging from 0 to 65535. Engineers use this to switch physical relay outputs on/off for controlling external devices like motors or switches. Setting this to 1 activates the relay, while 0 deactivates it to control connected electrical equipment.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.37758.1.20
snmpwalk -v2c -c public <target> ACTIDATA-MIB::relay1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.37758.1.20.1
snmpget -v2c -c public <target> ACTIDATA-MIB::relay1.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.37758.1.20.1 i <value>

Start monitoring Actidata tape backup/storage units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACTIDATA-MIB::relay1 OID value, configure state conditions and alerts, and monitor any Actidata tape backup/storage units from a single console.

How to Use in IPNetwork Monitor

Select an Actidata tape backup/storage unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type relay1 into the Find box to locate it in the OID tree, then select it and click OK. It reports the relay 1 output. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.37758actidataACTIDATA-MIB
1.3.6.1.4.1.37758.1consumerProductsACTIDATA-MIB
1.3.6.1.4.1.37758.1.20relay1ACTIDATA-MIB