ACMIB :: virtualUNIT308

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMIBvirtualUNIT308

virtualUNIT308

Module: ACMIB

OID (symbolic): ACMIB::virtualUNIT308

OID (numeric): 1.3.6.1.4.1.1751.2.18.5.19.1.16

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Timer T308 value - seconds

What is virtualUNIT308?

This sets the T308 signaling timer in seconds for handling DISCONNECT_ACKNOWLEDGE responses during connection tear-down procedures. Engineers adjust this timer to balance quick failure detection against the possibility of packet loss or delay during disconnection. A value of 30 seconds means the system waits up to 30 seconds for acknowledgment before retrying.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.5.19.1.16
snmpwalk -v2c -c public <target> ACMIB::virtualUNIT308

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.5.19.1.16.1
snmpget -v2c -c public <target> ACMIB::virtualUNIT308.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.18.5.19.1.16.1 i <value>

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::virtualUNIT308 OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.5intfConfigACMIB
1.3.6.1.4.1.1751.2.18.5.19virtualUNIConfigTableACMIB
1.3.6.1.4.1.1751.2.18.5.19.1virtualUNIConfigEntryACMIB
1.3.6.1.4.1.1751.2.18.5.19.1.16virtualUNIT308ACMIB