ACMIB :: sysInfoMisaligned

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMIBsysInfoMisaligned

sysInfoMisaligned

Module: ACMIB

OID (symbolic): ACMIB::sysInfoMisaligned

OID (numeric): 1.3.6.1.4.1.1751.2.18.19.18

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of misaligned cells received so far.

What is sysInfoMisaligned?

This OID counts the cumulative number of misaligned cells received by the device on an ATM connection. Network engineers use this counter to troubleshoot framing problems on high-speed links that can cause data loss and intermittent failures. A value of 87 means 87 cells arrived with incorrect byte alignment, suggesting a physical layer synchronization issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.19.18
snmpwalk -v2c -c public <target> ACMIB::sysInfoMisaligned

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.19.18.1
snmpget -v2c -c public <target> ACMIB::sysInfoMisaligned.1

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::sysInfoMisaligned OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.19sysInfoACMIB
1.3.6.1.4.1.1751.2.18.19.18sysInfoMisalignedACMIB