All MIBs › ACMIB › stratumCardMismatchNotify
stratumCardMismatchNotify
Module: ACMIB
OID (symbolic): ACMIB::stratumCardMismatchNotify
OID (numeric): 1.3.6.1.4.1.1751.2.18.8.1.48
Node type: NOTIFICATION-TYPE
Description: Critical : Indicates that the secondary stratum card does not support this mode of operation being applied to the primary stratum. Card must be upgraded.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' ACMIB::stratumCardMismatchNotify snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.1751.2.18.8.1.48
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:55774->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (513086942) 59 days, 9:14:29.42 SNMPv2-MIB::snmpTrapOID.0 = OID: ACMIB::stratumCardMismatchNotify
Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::stratumCardMismatchNotify OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1751 | lucent | ACMIB |
| 1.3.6.1.4.1.1751.2 | mibs | ACMIB |
| 1.3.6.1.4.1.1751.2.18 | acMIB | ACMIB |
| 1.3.6.1.4.1.1751.2.18.8 | sysTraps | ACMIB |
| 1.3.6.1.4.1.1751.2.18.8.1 | systemEvents | ACMIB |
| 1.3.6.1.4.1.1751.2.18.8.1.48 | stratumCardMismatchNotify | ACMIB |