Module: ACMIB

OID (symbolic): ACMIB::msRxDataClkSrcForDce

OID (numeric): 1.3.6.1.4.1.1751.2.18.2.4.1.12

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Receive data clock source for DCE localTiming: a local clock source is used. (e.g., from backplane (stratum) loopTiming: from remote This field is ignored if the local side is DTE

What is msRxDataClkSrcForDce?

This OID determines whether the DCE port recovers received data using a local reference clock or by extracting clock from the incoming data stream. This must be coordinated with the remote device's clock source to maintain synchronization and prevent slipping. Choosing loopTiming extracts and locks to the clock embedded in the incoming data from the remote device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.2.4.1.12
snmpwalk -v2c -c public <target> ACMIB::msRxDataClkSrcForDce

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.2.4.1.12.1
snmpget -v2c -c public <target> ACMIB::msRxDataClkSrcForDce.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.18.2.4.1.12.1 i <value>

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::msRxDataClkSrcForDce OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.2equipConfigACMIB
1.3.6.1.4.1.1751.2.18.2.4msPortConfigTableACMIB
1.3.6.1.4.1.1751.2.18.2.4.1msPortConfigEntryACMIB
1.3.6.1.4.1.1751.2.18.2.4.1.12msRxDataClkSrcForDceACMIB