All MIBs › ACMIB › gr303Aal2PvcVccConnectionStatus
gr303Aal2PvcVccConnectionStatus
Module: ACMIB
OID (symbolic): ACMIB::gr303Aal2PvcVccConnectionStatus
OID (numeric): 1.3.6.1.4.1.1751.2.18.6.37.1.14
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: One of the end interfaces of the connection is not in service.
The rest of the states apply to connections going through resource interfaces like DSP2 and FEC. These interfaces are dynamically allocated.
If an end interface and the resource interfaces are out of service, the status will be inactive because the end interfaces take priority.
What is gr303Aal2PvcVccConnectionStatus?
This read-only OID reports whether the voice connection is currently active (all interfaces in service) or inactive (one endpoint offline). Network engineers monitor this to detect voice trunk failures and degraded service before customers complain. Example: an "Active" status means both subscriber and trunk sides are working; "Inactive" means one end is offline and calls cannot establish.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.37.1.14 snmpwalk -v2c -c public <target> ACMIB::gr303Aal2PvcVccConnectionStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.37.1.14.1 snmpget -v2c -c public <target> ACMIB::gr303Aal2PvcVccConnectionStatus.1
Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::gr303Aal2PvcVccConnectionStatus OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1751 | lucent | ACMIB |
| 1.3.6.1.4.1.1751.2 | mibs | ACMIB |
| 1.3.6.1.4.1.1751.2.18 | acMIB | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6 | connectionConfig | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6.37 | gr303Aal2PvcVccTable | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6.37.1 | gr303Aal2PvcVccEntry | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6.37.1.14 | gr303Aal2PvcVccConnectionStatus | ACMIB |