ACMIB :: frUniN392

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMIBfrUniN392

frUniN392

Module: ACMIB

OID (symbolic): ACMIB::frUniN392

OID (numeric): 1.3.6.1.4.1.1751.2.18.5.6.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: error threshold. DTE:Mandatory, DCE:Mandatory

What is frUniN392?

Sets the error threshold, a counter ranging from 1 to 10, that triggers a link-down event when exceeded during LMI polling. Engineers configure this to control how sensitive the interface is to Frame Relay link failures; too low causes false alarms, too high delays fault detection. Setting it to 3 means the link is declared down only after 3 consecutive LMI status messages report errors.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.5.6.1.10
snmpwalk -v2c -c public <target> ACMIB::frUniN392

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.5.6.1.10.1
snmpget -v2c -c public <target> ACMIB::frUniN392.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.18.5.6.1.10.1 i <value>

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::frUniN392 OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.5intfConfigACMIB
1.3.6.1.4.1.1751.2.18.5.6frUniConfigTableACMIB
1.3.6.1.4.1.1751.2.18.5.6.1frUniConfigEntryACMIB
1.3.6.1.4.1.1751.2.18.5.6.1.10frUniN392ACMIB