Type: INTEGER

Access: read-write

Description: full status polling counter. DTE:Mandatory, DCE:N/A

What is frUniN391?

Specifies how many full status enquiry polling cycles to wait before sending the next full status message, with valid values from 1 to 255. Operators adjust this to balance link stability verification against bandwidth usage on the Frame Relay circuit. A value of 5 means the router will send a full status message every 5 polling cycles, helping detect permanent virtual circuit (PVC) changes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.5.6.1.9
snmpwalk -v2c -c public <target> ACMIB::frUniN391

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.5.6.1.9.1
snmpget -v2c -c public <target> ACMIB::frUniN391.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.18.5.6.1.9.1 i <value>

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::frUniN391 OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.5intfConfigACMIB
1.3.6.1.4.1.1751.2.18.5.6frUniConfigTableACMIB
1.3.6.1.4.1.1751.2.18.5.6.1frUniConfigEntryACMIB
1.3.6.1.4.1.1751.2.18.5.6.1.9frUniN391ACMIB