ACMIB :: atmSpvcVccStatsFrwdErrCrrctnRateB2A

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMIBatmSpvcVccStatsFrwdErrCrrctnRateB2A

atmSpvcVccStatsFrwdErrCrrctnRateB2A

Module: ACMIB

OID (symbolic): ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateB2A

OID (numeric): 1.3.6.1.4.1.1751.2.18.12.16.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Displays the Forward error correction rate being used by the FEC module in the B2A direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.

What is atmSpvcVccStatsFrwdErrCrrctnRateB2A?

This OID displays the Forward Error Correction rate applied to data traveling in the opposite direction, from endpoint B back to endpoint A. This allows asymmetric protection where the two directions of an ATM circuit can have different error-correction strengths based on their individual line quality. A value of 1-to-4 for B2A while A2B is 1-to-2 means the return path has noisier conditions requiring stronger error correction.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.12.16.1.17
snmpwalk -v2c -c public <target> ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateB2A

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.12.16.1.17.1
snmpget -v2c -c public <target> ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateB2A.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> atmSpvcVccStatsFrwdErrCrrctnRateB2A.1

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateB2A OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.12connectionStatisticsACMIB
1.3.6.1.4.1.1751.2.18.12.16atmSpvcVccStatsTableACMIB
1.3.6.1.4.1.1751.2.18.12.16.1atmSpvcVccStatsEntryACMIB
1.3.6.1.4.1.1751.2.18.12.16.1.17atmSpvcVccStatsFrwdErrCrrctnRateB2AACMIB