ACMIB :: atmSpvcVccStatsFrwdErrCrrctnRateA2B

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMIBatmSpvcVccStatsFrwdErrCrrctnRateA2B

atmSpvcVccStatsFrwdErrCrrctnRateA2B

Module: ACMIB

OID (symbolic): ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateA2B

OID (numeric): 1.3.6.1.4.1.1751.2.18.12.16.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Displays the Forward error correction rate being used by the FEC module in the A2B direction. This field is dynamic when Auto rates are selected. In other cases, it will display the rate set by the user.

What is atmSpvcVccStatsFrwdErrCrrctnRateA2B?

This OID displays the Forward Error Correction (FEC) coding rate currently applied to data traveling from endpoint A to endpoint B on this ATM circuit. Engineers care about this because higher FEC rates add overhead but protect against line errors, while lower rates save bandwidth but risk data loss on noisy circuits. A setting of 1-to-2 means one error-correction cell is added for every two data cells, recovering better from errors at the cost of 33% overhead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.12.16.1.16
snmpwalk -v2c -c public <target> ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateA2B

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.12.16.1.16.1
snmpget -v2c -c public <target> ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateA2B.1

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::atmSpvcVccStatsFrwdErrCrrctnRateA2B OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.12connectionStatisticsACMIB
1.3.6.1.4.1.1751.2.18.12.16atmSpvcVccStatsTableACMIB
1.3.6.1.4.1.1751.2.18.12.16.1atmSpvcVccStatsEntryACMIB
1.3.6.1.4.1.1751.2.18.12.16.1.16atmSpvcVccStatsFrwdErrCrrctnRateA2BACMIB