ACMIB :: atmSpvcVccRetryInterval

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMIBatmSpvcVccRetryInterval

atmSpvcVccRetryInterval

Module: ACMIB

OID (symbolic): ACMIB::atmSpvcVccRetryInterval

OID (numeric): 1.3.6.1.4.1.1751.2.18.6.18.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The time to wait before attempting to establish the SVC after a previous failed call attempt. A value of 0 indicates retry will be attempted immediately.

What is atmSpvcVccRetryInterval?

This OID sets the number of seconds (0-3600) to wait before attempting to re-establish a failed SPVC call. Network engineers adjust this to balance rapid reconnection for critical circuits against switch load from excessive retry storms. Setting this to 30 means if the initial SPVC setup fails, the switch will wait 30 seconds before trying again.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.18.1.5
snmpwalk -v2c -c public <target> ACMIB::atmSpvcVccRetryInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.18.1.5.1
snmpget -v2c -c public <target> ACMIB::atmSpvcVccRetryInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.18.6.18.1.5.1 i <value>

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::atmSpvcVccRetryInterval OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.6connectionConfigACMIB
1.3.6.1.4.1.1751.2.18.6.18atmSpvcVccActiveSvcTableACMIB
1.3.6.1.4.1.1751.2.18.6.18.1atmSpvcVccActiveSvcEntryACMIB
1.3.6.1.4.1.1751.2.18.6.18.1.5atmSpvcVccRetryIntervalACMIB