ACMIB :: atmSpvcVccRemoteSelectType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMIBatmSpvcVccRemoteSelectType

atmSpvcVccRemoteSelectType

Module: ACMIB

OID (symbolic): ACMIB::atmSpvcVccRemoteSelectType

OID (numeric): 1.3.6.1.4.1.1751.2.18.6.18.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Indicates whether the remote VPI/VCI values are to be used at the destination. If 'any' is used, the destination switch will choose the VPI/VCI values. In such a case, once the SPVC is connected, the value of this object will change to 'required', such that the same VPI/VCI values will continue to be used even if the connection is torn down and re-established. If the value 'required' is specified, the values: atmSpvcVccRemoteVpi and atmSpvcVccRemoteVci, must be supplied and are used at the destination.

What is atmSpvcVccRemoteSelectType?

This OID controls whether you specify exact VPI/VCI values at the destination or let the remote switch choose them automatically. Most production SPVC configurations specify 'required' to use fixed VPI/VCI pairs, ensuring the connection is consistent and predictable across restarts. If set to 'any', the remote switch picks free VPI/VCI values, but once connected this value changes to 'required' to lock those values for stability.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.18.1.2
snmpwalk -v2c -c public <target> ACMIB::atmSpvcVccRemoteSelectType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.18.1.2.1
snmpget -v2c -c public <target> ACMIB::atmSpvcVccRemoteSelectType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.18.6.18.1.2.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> atmSpvcVccRemoteSelectType.1

Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::atmSpvcVccRemoteSelectType OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
1.3.6.1.4.1.1751.2.18acMIBACMIB
1.3.6.1.4.1.1751.2.18.6connectionConfigACMIB
1.3.6.1.4.1.1751.2.18.6.18atmSpvcVccActiveSvcTableACMIB
1.3.6.1.4.1.1751.2.18.6.18.1atmSpvcVccActiveSvcEntryACMIB
1.3.6.1.4.1.1751.2.18.6.18.1.2atmSpvcVccRemoteSelectTypeACMIB