All MIBs › ACMIB › atmAtmSpvcVccRemoteSelectType
atmAtmSpvcVccRemoteSelectType
Module: ACMIB
OID (symbolic): ACMIB::atmAtmSpvcVccRemoteSelectType
OID (numeric): 1.3.6.1.4.1.1751.2.18.6.33.1.25
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Indicates whether the remote VPI/VCI values are to be used at the destination. If 'any' is used, the destination switch will choose the VPI/VCI values. In such a case, once the SPVC is connected, the value of this object will change to 'required', such that the same VPI/VCI values will continue to be used even if the connection is torn down and re-established. If the value 'required' is specified, the values: atmAtmSpvcVccRemoteVpi and atmAtmSpvcVccRemoteVci, must be supplied and are used at the destination.
What is atmAtmSpvcVccRemoteSelectType?
This OID determines whether the destination switch can choose the VPI/VCI values or whether specific values must be used for the remote end of the connection. Network engineers configure this to control how automatic VPI/VCI negotiation works during setup. For example, setting to 'any' lets the destination switch pick available identifiers, whereas 'required' locks in the specific VPI/VCI pair you provide.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.33.1.25 snmpwalk -v2c -c public <target> ACMIB::atmAtmSpvcVccRemoteSelectType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.18.6.33.1.25.1 snmpget -v2c -c public <target> ACMIB::atmAtmSpvcVccRemoteSelectType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.18.6.33.1.25.1 i <value>
Start monitoring Lucent/Nortel Access Concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMIB::atmAtmSpvcVccRemoteSelectType OID value, configure state conditions and alerts, and monitor any Lucent/Nortel Access Concentrator (legacy) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1751 | lucent | ACMIB |
| 1.3.6.1.4.1.1751.2 | mibs | ACMIB |
| 1.3.6.1.4.1.1751.2.18 | acMIB | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6 | connectionConfig | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6.33 | atmAtmSpvcVccTable | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6.33.1 | atmAtmSpvcVccEntry | ACMIB |
| 1.3.6.1.4.1.1751.2.18.6.33.1.25 | atmAtmSpvcVccRemoteSelectType | ACMIB |