Module: ACC-MIB

OID (symbolic): ACC-MIB::accSrPortFRencap

OID (numeric): 1.3.6.1.4.1.5.1.1.25.9.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Frame Relay Encapsulation Method

What is accSrPortFRencap?

This selects the Frame Relay encapsulation method the device uses, such as proprietary, RFC 1490, or RFC 2427 standard. You configure this to match your WAN provider's Frame Relay implementation and the remote equipment. Setting it to RFC1490 means industry-standard Frame Relay encapsulation with IP awareness is in use.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5.1.1.25.9.1.3
snmpwalk -v2c -c public <target> ACC-MIB::accSrPortFRencap

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5.1.1.25.9.1.3.1
snmpget -v2c -c public <target> ACC-MIB::accSrPortFRencap.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5.1.1.25.9.1.3.1 i <value>

Start monitoring ACC/Ericsson WAN access routers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACC-MIB::accSrPortFRencap OID value, configure state conditions and alerts, and monitor any ACC/Ericsson WAN access routers (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5accACC-MIB
1.3.6.1.4.1.5.1accSBARACC-MIB
1.3.6.1.4.1.5.1.1accBRGACC-MIB
1.3.6.1.4.1.5.1.1.25accSrACC-MIB
1.3.6.1.4.1.5.1.1.25.9accSrPortFRTableACC-MIB
1.3.6.1.4.1.5.1.1.25.9.1accSrPortFREntryACC-MIB
1.3.6.1.4.1.5.1.1.25.9.1.3accSrPortFRencapACC-MIB