A3COM-HUAWEI-WAPI-MIB :: h3cwapiStatsWAISignatureErrors

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › A3COM-HUAWEI-WAPI-MIB › h3cwapiStatsWAISignatureErrors

h3cwapiStatsWAISignatureErrors

Module: A3COM-HUAWEI-WAPI-MIB

OID (symbolic): A3COM-HUAWEI-WAPI-MIB::h3cwapiStatsWAISignatureErrors

OID (numeric): 1.3.6.1.4.1.43.45.1.10.2.77.2.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This counter increases when the received packet of WAI signature is wrong.

What is h3cwapiStatsWAISignatureErrors?

This Counter32 tracks the cumulative count of received WAI packets with invalid signatures throughout the device uptime. Engineers monitor this to detect cryptographic validation failures or compromised traffic. A rising counter indicates authentication challenges or potential security issues.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.77.2.1
snmpwalk -v2c -c public <target> A3COM-HUAWEI-WAPI-MIB::h3cwapiStatsWAISignatureErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.77.2.1.1
snmpget -v2c -c public <target> A3COM-HUAWEI-WAPI-MIB::h3cwapiStatsWAISignatureErrors.1

Start monitoring H3C/3Com wireless controllers and APs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A3COM-HUAWEI-WAPI-MIB::h3cwapiStatsWAISignatureErrors OID value, configure state conditions and alerts, and monitor any H3C/3Com wireless controllers and APs from a single console.

How to Use in IPNetwork Monitor

Select an H3C/3Com wireless controller or access point as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type h3cwapiStatsWAISignatureErrors into the Find box to locate it in the OID tree, then select it and click OK. This counter increases when the received packet of WAI signature is wrong. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-AUDL-R1-MIB
1.3.6.1.4.1.43.45jv_mibA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1huaweiA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10h3cA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10.2h3cCommonA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10.2.77h3cwapiMIBA3COM-HUAWEI-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.45.1.10.2.77.2h3cwapiMIBStatsObjectsA3COM-HUAWEI-WAPI-MIB
1.3.6.1.4.1.43.45.1.10.2.77.2.1h3cwapiStatsWAISignatureErrorsA3COM-HUAWEI-WAPI-MIB