A3COM-HUAWEI-SRM-MIB :: hw8060DevMRpuTemperature

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › A3COM-HUAWEI-SRM-MIB › hw8060DevMRpuTemperature

hw8060DevMRpuTemperature

Module: A3COM-HUAWEI-SRM-MIB

OID (symbolic): A3COM-HUAWEI-SRM-MIB::hw8060DevMRpuTemperature

OID (numeric): 1.3.6.1.4.1.43.45.1.2.33.20.1.7.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This variable indicates the temperature of RPU.

What is hw8060DevMRpuTemperature?

This integer OID reports the current temperature in degrees Celsius of the Route Processing Unit (RPU). Network engineers monitor it to detect thermal stress and ensure the device stays within safe operating limits. A typical value of 42 indicates normal operation; values above configured thresholds trigger alarms.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.45.1.2.33.20.1.7.1
snmpwalk -v2c -c public <target> A3COM-HUAWEI-SRM-MIB::hw8060DevMRpuTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.45.1.2.33.20.1.7.1.1
snmpget -v2c -c public <target> A3COM-HUAWEI-SRM-MIB::hw8060DevMRpuTemperature.1

Start monitoring Huawei 8060-series routers (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A3COM-HUAWEI-SRM-MIB::hw8060DevMRpuTemperature OID value, configure state conditions and alerts, and monitor any Huawei 8060-series routers (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Huawei 8060-series router (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hw8060DevMRpuTemperature into the Find box to locate it in the OID tree, then select it and click OK. This variable indicates the temperature of RPU. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-AUDL-R1-MIB
1.3.6.1.4.1.43.45jv_mibA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1huaweiA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.2hwproductsA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.2.33mlsrA3COM-HUAWEI-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.45.1.2.33.20aR46_E200A3COM-HUAWEI-SRM-MIB
1.3.6.1.4.1.43.45.1.2.33.20.1hw8060DevObjectsA3COM-HUAWEI-SRM-MIB
1.3.6.1.4.1.43.45.1.2.33.20.1.7dev8060MGlobalTableA3COM-HUAWEI-SRM-MIB
1.3.6.1.4.1.43.45.1.2.33.20.1.7.1hw8060DevMRpuTemperatureA3COM-HUAWEI-SRM-MIB