All MIBs › A3COM-HUAWEI-POWER-ETH-EXT-MIB › h3cPOEModuleOverTemp
h3cPOEModuleOverTemp
Module: A3COM-HUAWEI-POWER-ETH-EXT-MIB
OID (symbolic): A3COM-HUAWEI-POWER-ETH-EXT-MIB::h3cPOEModuleOverTemp
OID (numeric): 1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.6
Node type: OBJECT-TYPE
Type: ModuleAlarmState
Access: read-only
Description: The node specifies the alarm state: The temperature is too high. The value of this node is one of the following values: normal (1), alarm (2).
What is h3cPOEModuleOverTemp?
This OID monitors whether the power module's internal temperature exceeds safe limits, returning normal (1) or alarm (2). Sustained high temperatures indicate insufficient cooling and risk hardware failure or automatic shutdown. An alarm (2) reading means the module needs thermal intervention or replacement.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.6 snmpwalk -v2c -c public <target> A3COM-HUAWEI-POWER-ETH-EXT-MIB::h3cPOEModuleOverTemp
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.6.1 snmpget -v2c -c public <target> A3COM-HUAWEI-POWER-ETH-EXT-MIB::h3cPOEModuleOverTemp.1
Start monitoring H3C/3Com PoE switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A3COM-HUAWEI-POWER-ETH-EXT-MIB::h3cPOEModuleOverTemp OID value, configure state conditions and alerts, and monitor any H3C/3Com PoE switches from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.43 | a3Com | A3COM-BRIDGE-R3-MIB |
| 1.3.6.1.4.1.43.45 | jv_mib | A3COM-HUAWEI-OID-MIB |
| 1.3.6.1.4.1.43.45.1 | huawei | A3COM-HUAWEI-OID-MIB |
| 1.3.6.1.4.1.43.45.1.10 | h3c | A3COM-HUAWEI-OID-MIB |
| 1.3.6.1.4.1.43.45.1.10.2 | h3cCommon | A3COM-HUAWEI-OID-MIB |
| 1.3.6.1.4.1.43.45.1.10.2.14 | h3cPowerEthernetExt | A3COM-HUAWEI-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.43.45.1.10.2.14.8 | h3cPOEPowerObjects | A3COM-HUAWEI-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.43.45.1.10.2.14.8.7 | h3cPOEAlarmStateObjects | A3COM-HUAWEI-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.43.45.1.10.2.14.8.7.2 | h3cPOEAlarmStateInfoTable | A3COM-HUAWEI-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1 | h3cPOEAlarmStateInfoEntry | A3COM-HUAWEI-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.6 | h3cPOEModuleOverTemp | A3COM-HUAWEI-POWER-ETH-EXT-MIB |