h3cMplsPsSwitchCondition

Module: A3COM-HUAWEI-MPLSOAM-PS-MIB

OID (symbolic): A3COM-HUAWEI-MPLSOAM-PS-MIB::h3cMplsPsSwitchCondition

OID (numeric): 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.8

Node type: OBJECT-TYPE

Type: Integer32

Access: read-create

Description: The current switch condition of the protection group. 1: clear, this command clears all of the externally initiated switch commands listed below; 2: lockout of protection, fix the selector position on the working LSP, Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection, switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail, for 1:1, Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp, switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp, switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer, a configurable timer which is used to delay before reversion; 8: HoldOff-timer, the time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp

What is h3cMplsPsSwitchCondition?

Numeric status indicating the current protection-switching state or allows manual override commands on the group. Values range from 1 (clear conditions) to 9 (various forced switch modes); engineers set this to manually trigger failover or lock the selector. A value of 2 locks protection preventing unwanted switches.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-AUDL-R1-MIB
1.3.6.1.4.1.43.45jv_mibA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1huaweiA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10h3cA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10.2h3cCommonA3COM-HUAWEI-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.45.1.10.2.80h3cMplsOamPsA3COM-HUAWEI-MPLSOAM-PS-MIB
1.3.6.1.4.1.43.45.1.10.2.80.2h3cMplsOamPsTableA3COM-HUAWEI-MPLSOAM-PS-MIB
1.3.6.1.4.1.43.45.1.10.2.80.2.1h3cMplsPsTableA3COM-HUAWEI-MPLSOAM-PS-MIB
1.3.6.1.4.1.43.45.1.10.2.80.2.1.1h3cMplsPsEntryA3COM-HUAWEI-MPLSOAM-PS-MIB
1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.8h3cMplsPsSwitchConditionA3COM-HUAWEI-MPLSOAM-PS-MIB