A3COM-HUAWEI-EFM-COMMON-MIB :: h3cDot3OamErrSymPeriodWindowLo

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsA3COM-HUAWEI-EFM-COMMON-MIBh3cDot3OamErrSymPeriodWindowLo

h3cDot3OamErrSymPeriodWindowLo

Module: A3COM-HUAWEI-EFM-COMMON-MIB

OID (symbolic): A3COM-HUAWEI-EFM-COMMON-MIB::h3cDot3OamErrSymPeriodWindowLo

OID (numeric): 1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The two objects h3cDot3OamErrSymPeriodWindowHi and h3cDot3OamErrSymPeriodWindowLo together form an unsigned 64-bit integer representing the number of symbols over which this threshold event is defined. This is defined as

h3cDot3OamErrSymPeriodWindow = ((2^32)*h3cDot3OamErrSymPeriodWindowHi) + h3cDot3OamErrSymPeriodWindowLo

If h3cDot3OamErrSymPeriodThreshold symbol errors occur within a window of h3cDot3OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating the threshold has been crossed in this window.

What is h3cDot3OamErrSymPeriodWindowLo?

This Unsigned32 comprises the low 32 bits of the 64-bit symbol-error window size used for threshold calculations. Combined with WindowHi, it allows monitoring symbol errors across large time periods or symbol counts. A value like 1,000,000 symbols defines the observation window for error rate assessment.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1.2
snmpwalk -v2c -c public <target> A3COM-HUAWEI-EFM-COMMON-MIB::h3cDot3OamErrSymPeriodWindowLo

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1.2.1
snmpget -v2c -c public <target> A3COM-HUAWEI-EFM-COMMON-MIB::h3cDot3OamErrSymPeriodWindowLo.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1.2.1 i <value>

Start monitoring H3C/3Com/Huawei Ethernet switches and routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A3COM-HUAWEI-EFM-COMMON-MIB::h3cDot3OamErrSymPeriodWindowLo OID value, configure state conditions and alerts, and monitor any H3C/3Com/Huawei Ethernet switches and routers from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-BRIDGE-R3-MIB
1.3.6.1.4.1.43.45jv_mibA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1huaweiA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10h3cA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10.2h3cCommonA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10.2.42h3cEponA3COM-HUAWEI-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.45.1.10.2.42.3h3cEfmOamMIBA3COM-HUAWEI-EFM-COMMON-MIB
1.3.6.1.4.1.43.45.1.10.2.42.3.1h3cDot3OamMIBA3COM-HUAWEI-EFM-COMMON-MIB
1.3.6.1.4.1.43.45.1.10.2.42.3.1.5h3cDot3OamEventConfigTableA3COM-HUAWEI-EFM-COMMON-MIB
1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1h3cDot3OamEventConfigEntryA3COM-HUAWEI-EFM-COMMON-MIB
1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1.2h3cDot3OamErrSymPeriodWindowLoA3COM-HUAWEI-EFM-COMMON-MIB