A10-AX-TRAPS :: axNotificationSLBCurConns

MIB Reference — IPNetwork Monitor · Updated September 13, 2026

All MIBsA10-AX-TRAPSaxNotificationSLBCurConns

axNotificationSLBCurConns

Module: A10-AX-TRAPS

OID (symbolic): A10-AX-TRAPS::axNotificationSLBCurConns

OID (numeric): 1.3.6.1.4.1.22610.2.4.3.12.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The current total of connections.

What is axNotificationSLBCurConns?

A counter showing the current number of active connections to a server at the time of notification. Operators use this to assess load and validate threshold violations. A spike to 5000 connections might explain why a CPU threshold alarm fired.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22610.2.4.3.12.1.4
snmpwalk -v2c -c public <target> A10-AX-TRAPS::axNotificationSLBCurConns

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22610.2.4.3.12.1.4.1
snmpget -v2c -c public <target> A10-AX-TRAPS::axNotificationSLBCurConns.1

Start monitoring A10 Networks Thunder ADCs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A10-AX-TRAPS::axNotificationSLBCurConns OID value, configure state conditions and alerts, and monitor any A10 Networks Thunder ADCs from a single console.

How to Use in IPNetwork Monitor

Select an A10 Networks Thunder ADC as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type axNotificationSLBCurConns into the Find box to locate it in the OID tree, then select it and click OK. The current total of connections. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22610a10A10-COMMON-MIB
1.3.6.1.4.1.22610.2a10MgmtA10-COMMON-MIB
1.3.6.1.4.1.22610.2.4axMgmtA10-AX-MIB
1.3.6.1.4.1.22610.2.4.3axAppA10-AX-MIB
1.3.6.1.4.1.22610.2.4.3.12axNotificationA10-AX-MIB
1.3.6.1.4.1.22610.2.4.3.12.1axNotificationObjectsA10-AX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.22610.2.4.3.12.1.4axNotificationSLBCurConnsA10-AX-TRAPS