Telefonaktiebolaget LM Ericsson MIBs

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

« All organizations

1 module from Telefonaktiebolaget LM Ericsson

Ericsson's single module here, ERICSSON-ALARM-IRP-MIB, implements the 3GPP Alarm Integration Reference Point (IRP), a standardized telecom fault-management interface built on X.733 alarm concepts, rather than covering any specific piece of Ericsson hardware. It exposes summary counts of active alarms by severity (critical/major/minor/warning/indeterminate) plus a detailed active-alarm table identifying each alarm's managed-object class and instance, with notifications fired when alarms are raised or cleared. If you operate Ericsson telecom network elements or element managers reporting into a centralized fault-management platform, this module's severity counters and alarm table are what a NOC would trend for an at-a-glance view of an element's health, then drill into alarmManagedObjectInstance to pinpoint exactly which board or link raised a given alarm.

ModuleDescription
ERICSSON-ALARM-IRP-MIBImplements Ericsson's Alarm IRP (Integration Reference Point) for standardized fault management and alarm forwarding in telecom networks.