All MIBs › V2H124-24-MIB › bcastStormSampleType
bcastStormSampleType
Module: V2H124-24-MIB
OID (symbolic): V2H124-24-MIB::bcastStormSampleType
OID (numeric): 1.3.6.1.4.1.52.4.12.30.1.11.1.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Sample type. If this is pkt-rate(1), then bcastStormPktRate is used to specify the broadcast storm threshold. If this is octet-rate(2), then bcastStormOctetRate determines the broadcast storm threshold. If this is percent(3), then bcastStormPercent determines the threshold.
What is bcastStormSampleType?
Chooses which unit measures the broadcast-storm threshold for this port: pkt-rate(1) uses bcastStormPktRate, octet-rate(2) uses bcastStormOctetRate, and percent(3) uses bcastStormPercent as the value that triggers storm control.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.12.30.1.11.1.1.3 snmpwalk -v2c -c public <target> V2H124-24-MIB::bcastStormSampleType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.12.30.1.11.1.1.3.1 snmpget -v2c -c public <target> V2H124-24-MIB::bcastStormSampleType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.12.30.1.11.1.1.3.1 i <value>
Start monitoring Enterasys V2H124-24 stackable switches (per-unit firmware version/stack-role status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the V2H124-24-MIB::bcastStormSampleType OID value, configure state conditions and alerts, and monitor any Enterasys V2H124-24 stackable switches (per-unit firmware version/stack-role status) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.12 | ctronV2H | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.12.30 | v2h124_24MIB | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.12.30.1 | v2h124_24MIBObjects | V2H124-24-MIB |
| 1.3.6.1.4.1.52.4.12.30.1.11 | bcastStormMgt | V2H124-24-MIB |
| 1.3.6.1.4.1.52.4.12.30.1.11.1 | bcastStormTable | V2H124-24-MIB |
| 1.3.6.1.4.1.52.4.12.30.1.11.1.1 | bcastStormEntry | V2H124-24-MIB |
| 1.3.6.1.4.1.52.4.12.30.1.11.1.1.3 | bcastStormSampleType | V2H124-24-MIB |