TN-DEV-RFC2544-MIB :: tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TN-DEV-RFC2544-MIB › tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck

tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck

Module: TN-DEV-RFC2544-MIB

OID (symbolic): TN-DEV-RFC2544-MIB::tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck

OID (numeric): 1.3.6.1.4.1.868.2.5.3.1.1.42.2.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Sequence Number Check disable/enable of this table.

What is tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck?

This read-write value enables or disables sequence number checking for an RFC 2544 test profile's common parameters, with disable(0) and enable(1) as the options. Admins turn sequence checking on when they need the benchmark test to detect out-of-order or dropped test frames during the run, or off if that check isn't needed for the current test type. For example, enabling sequence number checking on a throughput test profile lets the test flag any reordering of test frames across the link under test.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.868.2.5.3.1.1.42.2.1.5
snmpwalk -v2c -c public <target> TN-DEV-RFC2544-MIB::tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.868.2.5.3.1.1.42.2.1.5.1
snmpget -v2c -c public <target> TN-DEV-RFC2544-MIB::tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.868.2.5.3.1.1.42.2.1.5.1 i <value>

Start monitoring Transition Networks, Inc. equipment (RFC 2544 benchmarking test-profile config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TN-DEV-RFC2544-MIB::tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheck OID value, configure state conditions and alerts, and monitor any Transition Networks, Inc. equipment (RFC 2544 benchmarking test-profile config status) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.868transitionTRANSITION-SMI
1.3.6.1.4.1.868.2productsTRANSITION-SMI
1.3.6.1.4.1.868.2.5tnProductsTRANSITION-SMI
1.3.6.1.4.1.868.2.5.3tnMgmtMIBTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1tnMgmtObjectsTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1.1tnDevMgmtTN-MGMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.868.2.5.3.1.1.42tnDevRFC2544TN-DEV-RFC2544-MIB
1.3.6.1.4.1.868.2.5.3.1.1.42.2tnDevRFC2544ProfileConfigurationCommonParametersTableTN-DEV-RFC2544-MIB
1.3.6.1.4.1.868.2.5.3.1.1.42.2.1tnDevRFC2544ProfileConfigurationCommonParametersEntryTN-DEV-RFC2544-MIB
1.3.6.1.4.1.868.2.5.3.1.1.42.2.1.5tnDevRFC2544ProfileConfigurationCommonParametersSequenceNumberCheckTN-DEV-RFC2544-MIB