TEMPUSLXUNISON-MIB :: gpsFaultStatus

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TEMPUSLXUNISON-MIB › gpsFaultStatus

gpsFaultStatus

Module: TEMPUSLXUNISON-MIB

OID (symbolic): TEMPUSLXUNISON-MIB::gpsFaultStatus

OID (numeric): 1.3.6.1.4.1.13827.6.1.1

Node type: OBJECT-TYPE

Type: Bits

Access: read-only

Description: This is a bit string contained in one character representing the least significant two nibbles of the GPS fault status word. Unfortunately, SNMP numbers the bits in the reverse order, so that the enumerated values are backwards from the description contained in the User's Manual for the fault status field returned by the gpsstat command. Each bit indicates a fault when set. Currently defined fault states encoded in this value:

Bit 7: DAC controlling the TCXO is near the high or low limit. Bit 6: Time Figure of Merit has been 9 (unsynchronized) for 1 hour. Bit 5: Field Programmable Gate Array (FPGA) did not configure properly. Bit 4: FLASH memory had a write fault. Bit 3: GPS engine communication fault. Bit 2: GPS reference time fault (fails sanity checks). Bit 1: NTP daemon is not polling the GPS reference clock. Bit 0: GPS antenna or feedline is shorted or open.

What is gpsFaultStatus?

A bitmask reporting up to eight distinct GPS sub-system fault conditions: antenna fault, NTP not polling, reference time sanity failure, GPS engine communication fault, flash write fault, FPGA misconfiguration, signal timeout, or DAC near limit; decode it to pinpoint exactly which GPS hardware fault is active.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.13827.6.1.1
snmpwalk -v2c -c public <target> TEMPUSLXUNISON-MIB::gpsFaultStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.13827.6.1.1.1
snmpget -v2c -c public <target> TEMPUSLXUNISON-MIB::gpsFaultStatus.1

Start monitoring EndRun Technologies Tempus LX/Unison GPS-synchronized NTP time server appliance (sync status/oscillator health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TEMPUSLXUNISON-MIB::gpsFaultStatus OID value, configure state conditions and alerts, and monitor any EndRun Technologies Tempus LX/Unison GPS-synchronized NTP time server appliance (sync status/oscillator health) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.13827endRunTechnologiesMIBENDRUNTECHNOLOGIES-MIB
Numeric OIDNameModule
1.3.6.1.4.1.13827.6tempuslxGntpTEMPUSLXUNISON-MIB
1.3.6.1.4.1.13827.6.1gpsTEMPUSLXUNISON-MIB
1.3.6.1.4.1.13827.6.1.1gpsFaultStatusTEMPUSLXUNISON-MIB