SIAE-ALARM-MIB :: alarmAntiFloodingLowWater

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSIAE-ALARM-MIBalarmAntiFloodingLowWater

alarmAntiFloodingLowWater

Module: SIAE-ALARM-MIB

OID (symbolic): SIAE-ALARM-MIB::alarmAntiFloodingLowWater

OID (numeric): 1.3.6.1.4.1.3373.1103.4.31

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines the threshold value of the number of event notifications, occurring during the observation period, below which an alarm exits the flooding state. The value being assigned to this leaf must be strictly lower than the current value of leaf alarmAntiFloodingHighWater.

What is alarmAntiFloodingLowWater?

The notification-rate threshold, 1-8, default 1, an alarm must drop below within a later observation window before it exits the flooding state; it must be set strictly lower than the current alarmAntiFloodingHighWater value.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3373.1103.4.31
snmpwalk -v2c -c public <target> SIAE-ALARM-MIB::alarmAntiFloodingLowWater

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3373.1103.4.31.1
snmpget -v2c -c public <target> SIAE-ALARM-MIB::alarmAntiFloodingLowWater.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3373.1103.4.31.1 i <value>

Start monitoring SIAE Microelettronica microwave radio and transport equipment, entire product line (active alarm table/transition log) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SIAE-ALARM-MIB::alarmAntiFloodingLowWater OID value, configure state conditions and alerts, and monitor any SIAE Microelettronica microwave radio and transport equipment, entire product line (active alarm table/transition log) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3373siaeMicroelettronicaSpaSIAE-TREE-MIB
1.3.6.1.4.1.3373.1103siaeMibSIAE-TREE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3373.1103.4smalarmSIAE-ALARM-MIB
1.3.6.1.4.1.3373.1103.4.31alarmAntiFloodingLowWaterSIAE-ALARM-MIB