S5-ETHERNET-COMMON-MIB :: s5EnBStatGoodOctets

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › S5-ETHERNET-COMMON-MIB › s5EnBStatGoodOctets

s5EnBStatGoodOctets

Module: S5-ETHERNET-COMMON-MIB

OID (symbolic): S5-ETHERNET-COMMON-MIB::s5EnBStatGoodOctets

OID (numeric): 1.3.6.1.4.1.45.1.6.6.2.1.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: A count of octets contained in frames received which had no errors.

This counter includes octets in unicast, broadcast, and multicast frames. This counter includes octets after the start frame delimiter up to FCS but not including FCS octets.

What is s5EnBStatGoodOctets?

A running count of octets in error-free received frames (unicast, broadcast, and multicast combined, counted from the start frame delimiter up to but excluding the FCS), the basic good-throughput byte counter for this source.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.45.1.6.6.2.1.1.2
snmpwalk -v2c -c public <target> S5-ETHERNET-COMMON-MIB::s5EnBStatGoodOctets

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.45.1.6.6.2.1.1.2.1
snmpget -v2c -c public <target> S5-ETHERNET-COMMON-MIB::s5EnBStatGoodOctets.1

Start monitoring Avaya/Nortel BayStack Ethernet switches (shared per-port link/jabber/partition status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the S5-ETHERNET-COMMON-MIB::s5EnBStatGoodOctets OID value, configure state conditions and alerts, and monitor any Avaya/Nortel BayStack Ethernet switches (shared per-port link/jabber/partition status) from a single console.

How to Use in IPNetwork Monitor

Select an Avaya/Nortel BayStack Ethernet switch (shared per-port link/jabber/partition status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type s5EnBStatGoodOctets into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports a count of octets contained in frames received which had no errors. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.45synopticsCMU-MIB
1.3.6.1.4.1.45.1productsSYNOPTICS-ROOT-MIB
1.3.6.1.4.1.45.1.6series5000SYNOPTICS-ROOT-MIB
1.3.6.1.4.1.45.1.6.6s5EthS5-ROOT-MIB
1.3.6.1.4.1.45.1.6.6.2s5EnStatS5-ETHERNET-MIB
Numeric OIDNameModule
1.3.6.1.4.1.45.1.6.6.2.1s5EnBStatTableS5-ETHERNET-COMMON-MIB
1.3.6.1.4.1.45.1.6.6.2.1.1s5EnBStatEntryS5-ETHERNET-COMMON-MIB
1.3.6.1.4.1.45.1.6.6.2.1.1.2s5EnBStatGoodOctetsS5-ETHERNET-COMMON-MIB