All MIBs › S5-ETH-REDUNDANT-LINKS-MIB › s5EnRedPortRemFltSelectMode
s5EnRedPortRemFltSelectMode
Module: S5-ETH-REDUNDANT-LINKS-MIB
OID (symbolic): S5-ETH-REDUNDANT-LINKS-MIB::s5EnRedPortRemFltSelectMode
OID (numeric): 1.3.6.1.4.1.45.1.6.6.1.2.1.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This mode specifies the set of local fault events which will cause a switchover. The values are: synoptics(1)..The SynOptics Tx Remote Fault events consist of auto-partition and NM (network management) partition events in addition to the standard events. standard(2)...The standard events are link-off for all ports, and low light, jabber, Rx invalid idle, Tx dark, and Tx remote fault (for diagnostics) for ports with transmit remote fault capability.
What is s5EnRedPortRemFltSelectMode?
This read-write object selects which set of local fault conditions will trigger a switchover on this port: synoptics adds SynOptics-specific auto-partition and network-management partition events on top of the standard set, while standard uses only link-off, low light, jabber, and similar baseline events. An admin sets this to synoptics when the redundant hardware supports SynOptics proprietary remote-fault signaling and they want the extra fault conditions recognized, or standard for baseline fault detection. This choice directly affects how sensitive the automatic redundancy switchover is to marginal link conditions.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.45.1.6.6.1.2.1.1.7 snmpwalk -v2c -c public <target> S5-ETH-REDUNDANT-LINKS-MIB::s5EnRedPortRemFltSelectMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.45.1.6.6.1.2.1.1.7.1 snmpget -v2c -c public <target> S5-ETH-REDUNDANT-LINKS-MIB::s5EnRedPortRemFltSelectMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.45.1.6.6.1.2.1.1.7.1 i <value>
Start monitoring Nortel/Avaya BayStack switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the S5-ETH-REDUNDANT-LINKS-MIB::s5EnRedPortRemFltSelectMode OID value, configure state conditions and alerts, and monitor any Nortel/Avaya BayStack switches from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.45 | synoptics | CMU-MIB |
| 1.3.6.1.4.1.45.1 | products | SYNOPTICS-ROOT-MIB |
| 1.3.6.1.4.1.45.1.6 | series5000 | SYNOPTICS-ROOT-MIB |
| 1.3.6.1.4.1.45.1.6.6 | s5Eth | S5-ROOT-MIB |
| 1.3.6.1.4.1.45.1.6.6.1 | s5EnCfg | S5-ETHERNET-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.45.1.6.6.1.2 | s5EnRedun | S5-ETH-REDUNDANT-LINKS-MIB |
| 1.3.6.1.4.1.45.1.6.6.1.2.1 | s5EnRedPortTable | S5-ETH-REDUNDANT-LINKS-MIB |
| 1.3.6.1.4.1.45.1.6.6.1.2.1.1 | s5EnRedPortEntry | S5-ETH-REDUNDANT-LINKS-MIB |
| 1.3.6.1.4.1.45.1.6.6.1.2.1.1.7 | s5EnRedPortRemFltSelectMode | S5-ETH-REDUNDANT-LINKS-MIB |