RC-SLPP-MIB :: rcSlppTimeout

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsRC-SLPP-MIBrcSlppTimeout

rcSlppTimeout

Module: RC-SLPP-MIB

OID (symbolic): RC-SLPP-MIB::rcSlppTimeout

OID (numeric): 1.3.6.1.4.1.2272.1.64.1.1.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This value specifies the time period for which a port will remain disabled. When SLPP disables a port, after this time period expires, the port will become re-enabled. A value of 0 means ports will never be re-enabled.

What is rcSlppTimeout?

How long, in seconds (0-65535, default 0), a port stays disabled after SLPP shuts it down for a detected loop before it is automatically re-enabled; a value of 0 means the port stays disabled until an admin manually re-enables it. An admin sets a nonzero timeout to let a transient loop condition clear and the port recover on its own, or leaves it at 0 to force manual intervention on every loop event.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2272.1.64.1.1.1.4
snmpwalk -v2c -c public <target> RC-SLPP-MIB::rcSlppTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2272.1.64.1.1.1.4.1
snmpget -v2c -c public <target> RC-SLPP-MIB::rcSlppTimeout.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2272.1.64.1.1.1.4.1 i <value>

Start monitoring Nortel/Avaya Ethernet Routing Switch, Bay Networks Rapid-City switch (Simple Loop Prevention Protocol) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RC-SLPP-MIB::rcSlppTimeout OID value, configure state conditions and alerts, and monitor any Nortel/Avaya Ethernet Routing Switch, Bay Networks Rapid-City switch (Simple Loop Prevention Protocol) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2272rapidCityRAPID-CITY
1.3.6.1.4.1.2272.1rcMgmtRAPID-CITY
1.3.6.1.4.1.2272.1.64rcSlppRAPID-CITY
1.3.6.1.4.1.2272.1.64.1rcSlppMibRAPID-CITY
1.3.6.1.4.1.2272.1.64.1.1rcSlppObjectsRAPID-CITY
1.3.6.1.4.1.2272.1.64.1.1.1rcSlppScalarsRAPID-CITY
Numeric OIDNameModule
1.3.6.1.4.1.2272.1.64.1.1.1.4rcSlppTimeoutRC-SLPP-MIB