PowerConnect3248-MIB :: mirrorType

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › PowerConnect3248-MIB › mirrorType

mirrorType

Module: PowerConnect3248-MIB

OID (symbolic): PowerConnect3248-MIB::mirrorType

OID (numeric): 1.3.6.1.4.1.674.10895.3.1.8.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-create

Description: If this value is rx(1), receive packets will be mirrored. If this value is tx(2), transmit packets will be mirrored. If this value is both(3), both receive and transmit packets.

What is mirrorType?

Selects which traffic direction is mirrored from the source port: rx(1) for received packets only, tx(2) for transmitted packets only, or both(3) for both directions.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10895dellLanDell-Vendor-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10895.3powerConnect3248MIBPowerConnect3248-MIB
1.3.6.1.4.1.674.10895.3.1powerConnect3248MIBObjectsPowerConnect3248-MIB
1.3.6.1.4.1.674.10895.3.1.8mirrorMgtPowerConnect3248-MIB
1.3.6.1.4.1.674.10895.3.1.8.1mirrorTablePowerConnect3248-MIB
1.3.6.1.4.1.674.10895.3.1.8.1.1mirrorEntryPowerConnect3248-MIB
1.3.6.1.4.1.674.10895.3.1.8.1.1.3mirrorTypePowerConnect3248-MIB