prvtOprLedSatus

Module: PRVT-OPR-LED-MANAGEMENT-MIB

OID (symbolic): PRVT-OPR-LED-MANAGEMENT-MIB::prvtOprLedSatus

OID (numeric): 1.3.6.1.4.1.738.1.5.110.1.1

Node type: OBJECT-TYPE

Type: LedValues

Access: read-write

Description: All possible led states. States red-stable and red-blinking can not be set. States amber-stable and amber-blinking green-blinking can be set only when the current state is green-stable. The object has read-write access and its default value is green-stable

What is prvtOprLedSatus?

This object reports or sets the current color/blink state of an operator-panel LED, cycling through values such as green-stable, amber-stable, amber-blinking, and green-blinking, with the red states reserved as read-only fault indications that cannot be written. An administrator can set it to change the LED's indicated state (for example to trigger an amber blink for attention) but only when the LED is currently in the green-stable state, and it defaults back to green-stable. For example, setting this object to amber-blinking would make the unit's status LED flash amber to signal a maintenance condition to someone standing at the device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.110.1.1
snmpwalk -v2c -c public <target> PRVT-OPR-LED-MANAGEMENT-MIB::prvtOprLedSatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.110.1.1.1
snmpget -v2c -c public <target> PRVT-OPR-LED-MANAGEMENT-MIB::prvtOprLedSatus.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.738.1.5.110.1.1.1 s <value>

Start monitoring BATM Advanced Communication switches (OPR status LED control) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-OPR-LED-MANAGEMENT-MIB::prvtOprLedSatus OID value, configure state conditions and alerts, and monitor any BATM Advanced Communication switches (OPR status LED control) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.110prvtOprLedMgmtMIBPRVT-OPR-LED-MANAGEMENT-MIB
1.3.6.1.4.1.738.1.5.110.1prvtOprLedMgmtObjectsPRVT-OPR-LED-MANAGEMENT-MIB
1.3.6.1.4.1.738.1.5.110.1.1prvtOprLedSatusPRVT-OPR-LED-MANAGEMENT-MIB