PROXY-MIB :: proxyHTTPMissSvcTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PROXY-MIB › proxyHTTPMissSvcTime

proxyHTTPMissSvcTime

Module: PROXY-MIB

OID (symbolic): PROXY-MIB::proxyHTTPMissSvcTime

OID (numeric): 1.3.6.1.3.25.17.3.3.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The service time for all HTTP misses.

What is proxyHTTPMissSvcTime?

The median service time specifically for HTTP requests that missed the cache and had to be fetched from an origin server; an admin compares this against proxyHTTPHitSvcTime to quantify how much latency the cache is actually saving users.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.3.25.17.3.3.1.3
snmpwalk -v2c -c public <target> PROXY-MIB::proxyHTTPMissSvcTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.3.25.17.3.3.1.3.1
snmpget -v2c -c public <target> PROXY-MIB::proxyHTTPMissSvcTime.1

Start monitoring Internet proxy/cache servers, e.g. Squid-based caching proxies with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PROXY-MIB::proxyHTTPMissSvcTime OID value, configure state conditions and alerts, and monitor any Internet proxy/cache servers, e.g. Squid-based caching proxies from a single console.

OID Breakdown

Upper-level ancestors (5 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.3experimentalAPERTUS-NPG-MIB
Numeric OIDNameModule
1.3.6.1.3.25nsfnetPROXY-MIB
1.3.6.1.3.25.17proxyPROXY-MIB
1.3.6.1.3.25.17.3proxyPerfPROXY-MIB
1.3.6.1.3.25.17.3.3proxyMedianSvcTablePROXY-MIB
1.3.6.1.3.25.17.3.3.1proxyMedianSvcEntryPROXY-MIB
1.3.6.1.3.25.17.3.3.1.3proxyHTTPMissSvcTimePROXY-MIB