PACKETLOGIC-MIB :: packetprocessingUptimeVal

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPACKETLOGIC-MIBpacketprocessingUptimeVal

packetprocessingUptimeVal

Module: PACKETLOGIC-MIB

OID (symbolic): PACKETLOGIC-MIB::packetprocessingUptimeVal

OID (numeric): 1.3.6.1.4.1.15397.2.1.8.17.1

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: CPU uptime

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.15397.2.1.8.17.1
snmpwalk -v2c -c public <target> PACKETLOGIC-MIB::packetprocessingUptimeVal

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.15397.2.1.8.17.1.1
snmpget -v2c -c public <target> PACKETLOGIC-MIB::packetprocessingUptimeVal.1

Start monitoring Procera Networks PacketLogic DPI appliance (packet-processing performance) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PACKETLOGIC-MIB::packetprocessingUptimeVal OID value, configure state conditions and alerts, and monitor any Procera Networks PacketLogic DPI appliance (packet-processing performance) from a single console.

How to Use in IPNetwork Monitor

Select a Procera Networks PacketLogic DPI appliance as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type packetprocessingUptimeVal into the Find box to locate it in the OID tree, then select it and click OK. It reports, in TimeTicks, how long the PacketLogic appliance's packet-processing CPU has been running since its last restart. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the uptime resets to a small value unexpectedly, which indicates the packet-processing engine restarted. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.15397proceraPACKETLOGIC-MIB
1.3.6.1.4.1.15397.2packetlogic2PACKETLOGIC-MIB
1.3.6.1.4.1.15397.2.1sysdiagPACKETLOGIC-MIB
1.3.6.1.4.1.15397.2.1.8packetprocessingPACKETLOGIC-MIB
1.3.6.1.4.1.15397.2.1.8.17packetprocessingUptimePACKETLOGIC-MIB
1.3.6.1.4.1.15397.2.1.8.17.1packetprocessingUptimeValPACKETLOGIC-MIB