dot11RetryCount

Module: NWA1123-NI

OID (symbolic): NWA1123-NI::dot11RetryCount

OID (numeric): 1.3.6.1.4.1.890.1.15.3.5.3.1.2

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: This counter shall increment when an MSDU is successfully transmitted after one or more retransmissions.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.890.1.15.3.5.3.1.2
snmpwalk -v2c -c public <target> NWA1123-NI::dot11RetryCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.890.1.15.3.5.3.1.2.1
snmpget -v2c -c public <target> NWA1123-NI::dot11RetryCount.1

Start monitoring ZyXEL NWA1123-NI 802.11n wireless access point with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NWA1123-NI::dot11RetryCount OID value, configure state conditions and alerts, and monitor any ZyXEL NWA1123-NI 802.11n wireless access point from a single console.

How to Use in IPNetwork Monitor

Select a ZyXEL NWA1123-NI 802.11n wireless access point as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dot11RetryCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This counter shall increment when an MSDU is successfully transmitted after one or more retransmissions. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.890zyxelIES5206-MIB
1.3.6.1.4.1.890.1productsIES5206-MIB
1.3.6.1.4.1.890.1.15nwa1100nhNWA1100-NH
1.3.6.1.4.1.890.1.15.3esMgmtNWA1100-NH
1.3.6.1.4.1.890.1.15.3.5esWirelessNWA1100-NH
1.3.6.1.4.1.890.1.15.3.5.3wlanStatisticTableNWA1100-NH
1.3.6.1.4.1.890.1.15.3.5.3.1wlanStatisticEntryNWA1100-NH
Numeric OIDNameModule
1.3.6.1.4.1.890.1.15.3.5.3.1.2dot11RetryCountNWA1123-NI