NBS-FECPM-MIB :: nbsFecpmRunningBitErrCor

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NBS-FECPM-MIB › nbsFecpmRunningBitErrCor

nbsFecpmRunningBitErrCor

Module: NBS-FECPM-MIB

OID (symbolic): NBS-FECPM-MIB::nbsFecpmRunningBitErrCor

OID (numeric): 1.3.6.1.4.1.629.223.4.3.1.10

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The total count of Bit Errors Corrected since boot-up; it may be the sum of nbsFecpmRunningCorBit0to1 and nbsFecpmRunningCorBit1to0.

What is nbsFecpmRunningBitErrCor?

The total count of FEC bit errors corrected since boot-up; may equal the sum of nbsFecpmRunningCorBit0to1 and nbsFecpmRunningCorBit1to0.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.223.4.3.1.10
snmpwalk -v2c -c public <target> NBS-FECPM-MIB::nbsFecpmRunningBitErrCor

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.223.4.3.1.10.1
snmpget -v2c -c public <target> NBS-FECPM-MIB::nbsFecpmRunningBitErrCor.1

Start monitoring NBase-Xyplex OTN/optical transport platform (FEC performance monitoring) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-FECPM-MIB::nbsFecpmRunningBitErrCor OID value, configure state conditions and alerts, and monitor any NBase-Xyplex OTN/optical transport platform (FEC performance monitoring) from a single console.

How to Use in IPNetwork Monitor

Select a NBase-Xyplex OTN/optical transport platform (FEC performance monitoring) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type nbsFecpmRunningBitErrCor into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total count of Bit Errors Corrected since boot-up; it may be the sum of nbsFecpmRunningCorBit0to1 and nbsFecpmRunningCorBit1to0. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseCORE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.223nbsFecpmMibNBS-FECPM-MIB
1.3.6.1.4.1.629.223.4nbsFecpmRunningGrpNBS-FECPM-MIB
1.3.6.1.4.1.629.223.4.3nbsFecpmRunningTableNBS-FECPM-MIB
1.3.6.1.4.1.629.223.4.3.1nbsFecpmRunningEntryNBS-FECPM-MIB
1.3.6.1.4.1.629.223.4.3.1.10nbsFecpmRunningBitErrCorNBS-FECPM-MIB