All MIBs › MRV-IR-HDAM-MIB › irHdamPowerStatus
irHdamPowerStatus
Module: MRV-IR-HDAM-MIB
OID (symbolic): MRV-IR-HDAM-MIB::irHdamPowerStatus
OID (numeric): 1.3.6.1.4.1.33.100.4.1.3.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The overall status of the power unit.
What is irHdamPowerStatus?
This reports the overall status of this HDAM power supply: on(1), off(2), or failed(3). Admins treat failed(3) as the clearest signal that a power supply module needs physical replacement, distinct from a supply that's merely switched off.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33.100.4.1.3.1.6 snmpwalk -v2c -c public <target> MRV-IR-HDAM-MIB::irHdamPowerStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.33.100.4.1.3.1.6.1 snmpget -v2c -c public <target> MRV-IR-HDAM-MIB::irHdamPowerStatus.1
Start monitoring MRV In-Reach LX HDAM expansion module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MRV-IR-HDAM-MIB::irHdamPowerStatus OID value, configure state conditions and alerts, and monitor any MRV In-Reach LX HDAM expansion module from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.33 | iTouch | ITOUCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.33.100 | mrvLx | MRV-IR-HDAM-MIB |
| 1.3.6.1.4.1.33.100.4 | irHdamMib | MRV-IR-HDAM-MIB |
| 1.3.6.1.4.1.33.100.4.1 | irHdam | MRV-IR-HDAM-MIB |
| 1.3.6.1.4.1.33.100.4.1.3 | irHdamPowerSupplyTable | MRV-IR-HDAM-MIB |
| 1.3.6.1.4.1.33.100.4.1.3.1 | irHdamPowerSupplyEntry | MRV-IR-HDAM-MIB |
| 1.3.6.1.4.1.33.100.4.1.3.1.6 | irHdamPowerStatus | MRV-IR-HDAM-MIB |