MRV-IR-CHAR-MIB :: irCharPortTransmitBytes

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MRV-IR-CHAR-MIB › irCharPortTransmitBytes

irCharPortTransmitBytes

Module: MRV-IR-CHAR-MIB

OID (symbolic): MRV-IR-CHAR-MIB::irCharPortTransmitBytes

OID (numeric): 1.3.6.1.4.1.33.100.2.3.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of bytes transmitted on the port.

What is irCharPortTransmitBytes?

Counts the total bytes the device has transmitted out this serial port since the counter was last reset, useful for confirming a console session is actively sending data.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33.100.2.3.1.1
snmpwalk -v2c -c public <target> MRV-IR-CHAR-MIB::irCharPortTransmitBytes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.33.100.2.3.1.1.1
snmpget -v2c -c public <target> MRV-IR-CHAR-MIB::irCharPortTransmitBytes.1

Start monitoring MRV In-Reach/LX console server (character-mode serial port config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MRV-IR-CHAR-MIB::irCharPortTransmitBytes OID value, configure state conditions and alerts, and monitor any MRV In-Reach/LX console server (character-mode serial port config) from a single console.

How to Use in IPNetwork Monitor

Select an MRV In-Reach/LX console server (character-mode serial port config) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type irCharPortTransmitBytes into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of bytes transmitted on the port. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.33xyplexCMU-MIB
1.3.6.1.4.1.33.100mrvLxMRV-IR-HDAM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.33.100.2irCharMibMRV-IR-CHAR-MIB
1.3.6.1.4.1.33.100.2.3irCharPortStatsTableMRV-IR-CHAR-MIB
1.3.6.1.4.1.33.100.2.3.1irCharPortStatsEntryMRV-IR-CHAR-MIB
1.3.6.1.4.1.33.100.2.3.1.1irCharPortTransmitBytesMRV-IR-CHAR-MIB