MOXA-IO-E1242-MIB :: systemTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-IO-E1242-MIB › systemTime

systemTime

Module: MOXA-IO-E1242-MIB

OID (symbolic): MOXA-IO-E1242-MIB::systemTime

OID (numeric): 1.3.6.1.4.1.8691.10.1242.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: I/O server up time (in seconds).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.10.1242.3
snmpwalk -v2c -c public <target> MOXA-IO-E1242-MIB::systemTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.10.1242.3.1
snmpget -v2c -c public <target> MOXA-IO-E1242-MIB::systemTime.1

Start monitoring Moxa ioLogik E1242 remote Ethernet I/O module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-IO-E1242-MIB::systemTime OID value, configure state conditions and alerts, and monitor any Moxa ioLogik E1242 remote Ethernet I/O module from a single console.

How to Use in IPNetwork Monitor

Select a Moxa ioLogik E1242 remote Ethernet I/O module as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type systemTime into the Find box to locate it in the OID tree, then select it and click OK. It reports i/O server up time (in seconds). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691.10ioLogikMOXA-IO-E1242-MIB
1.3.6.1.4.1.8691.10.1242e1242MOXA-IO-E1242-MIB
1.3.6.1.4.1.8691.10.1242.3systemTimeMOXA-IO-E1242-MIB