MOXA-CN2600-MIB :: socketTcpAliveCheck

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-CN2600-MIB › socketTcpAliveCheck

socketTcpAliveCheck

Module: MOXA-CN2600-MIB

OID (symbolic): MOXA-CN2600-MIB::socketTcpAliveCheck

OID (numeric): 1.3.6.1.4.1.8691.2.11.1.4.1.2.2.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The TCP alive check time. 0 min: TCP connection will not be closed when the TCP connection is idle. 1 to 99 min: The Terminal Server CN2600 series device server automatically closes the TCP connection if there is no TCP activity for the given time. After the connection is closed, the Terminal Server CN2600 series device server starts listening for another connection.

What is socketTcpAliveCheck?

TCP keepalive timeout for a port running in TCP Socket mode: 0 disables it, 1-99 minutes closes an idle TCP connection so the port frees up to listen for a new one.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.2.1.1.1
snmpwalk -v2c -c public <target> MOXA-CN2600-MIB::socketTcpAliveCheck

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.2.1.1.1.1
snmpget -v2c -c public <target> MOXA-CN2600-MIB::socketTcpAliveCheck.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.2.1.1.1.1 i <value>

Start monitoring Moxa CN2600 serial device/terminal server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-CN2600-MIB::socketTcpAliveCheck OID value, configure state conditions and alerts, and monitor any Moxa CN2600 serial device/terminal server from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2nportMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11cn2600MOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1swMgmtMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4portSettingMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1opModeSettingMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2applicationMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.2socketMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.2.1socketTableMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.2.1.1socketEntryMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.2.1.1.1socketTcpAliveCheckMOXA-CN2600-MIB