MOXA-CN2600-MIB :: redundantComMaxConnection

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-CN2600-MIB › redundantComMaxConnection

redundantComMaxConnection

Module: MOXA-CN2600-MIB

OID (symbolic): MOXA-CN2600-MIB::redundantComMaxConnection

OID (numeric): 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specific host can access this port of the Terminal Server CN2600 series device server, and the Redundant COM driver on that host will have full control over the port. Max. connection = 1: Allows only a single host��s Redundant COM driver to open the specific Terminal Server CN2600 series device server��s serial port. Max connection = 2 to 4: Allows 2 to 4 hosts�� Redundant COM drivers to open the specific Terminal Server CN2600 series device server��s serial port, at the same time. When multiple hosts�� Redundant COM drivers open the serial port at the same time, the COM driver only provides a pure data tunnel without control ability. The serial port parameter will use the firmware settings instead of getting the settings from your application program (AP).

What is redundantComMaxConnection?

The number of hosts' Redundant COM drivers allowed to open this serial port simultaneously, from 1 (single host with full control) up to 4 (shared, data-tunnel-only access with settings taken from firmware instead of the host application), used for redundant-COM applications with multiple monitoring hosts.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.1
snmpwalk -v2c -c public <target> MOXA-CN2600-MIB::redundantComMaxConnection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.1.1
snmpget -v2c -c public <target> MOXA-CN2600-MIB::redundantComMaxConnection.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.1.1 i <value>

Start monitoring Moxa CN2600 serial device/terminal server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-CN2600-MIB::redundantComMaxConnection OID value, configure state conditions and alerts, and monitor any Moxa CN2600 serial device/terminal server from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2nportMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11cn2600MOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1swMgmtMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4portSettingMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1opModeSettingMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2applicationMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3redundantComMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1redundantComTableMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1redundantComEntryMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.1redundantComMaxConnectionMOXA-CN2600-MIB