All MIBs › MOXA-CN2600-MIB › redundantComConnectionDownRTS
redundantComConnectionDownRTS
Module: MOXA-CN2600-MIB
OID (symbolic): MOXA-CN2600-MIB::redundantComConnectionDownRTS
OID (numeric): 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: For some applications, serial devices must obtain the Ethernet link status by reading the RTS signal from the Terminal Server CN2600 series device server. If this setting is set to 'always low,' RTS will change its state to low if the Ethernet link is off.
What is redundantComConnectionDownRTS?
Sets what the RTS signal on a Redundant COM port does when the Ethernet link goes down: always-low(1) forces RTS low so attached serial equipment can detect the network outage, always-high(0) leaves it unaffected.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.4 snmpwalk -v2c -c public <target> MOXA-CN2600-MIB::redundantComConnectionDownRTS
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.4.1 snmpget -v2c -c public <target> MOXA-CN2600-MIB::redundantComConnectionDownRTS.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.4.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> redundantComConnectionDownRTS.1
Start monitoring Moxa CN2600 serial device/terminal server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-CN2600-MIB::redundantComConnectionDownRTS OID value, configure state conditions and alerts, and monitor any Moxa CN2600 serial device/terminal server from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.8691 | moxa | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2 | nport | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11 | cn2600 | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1 | swMgmt | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1.4 | portSetting | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1.4.1 | opModeSetting | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1.4.1.2 | application | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1.4.1.2.3 | redundantCom | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1 | redundantComTable | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1 | redundantComEntry | MOXA-CN2600-MIB |
| 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.4 | redundantComConnectionDownRTS | MOXA-CN2600-MIB |