MOXA-CN2600-MIB :: redundantComAllowDriverControl

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-CN2600-MIB › redundantComAllowDriverControl

redundantComAllowDriverControl

Module: MOXA-CN2600-MIB

OID (symbolic): MOXA-CN2600-MIB::redundantComAllowDriverControl

OID (numeric): 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: If Max connection is greater than 1, CN2600 will ignore driver control commands from all connected hosts. However, if you set Allow driver control to YES, control commands will be accepted. Note that since the Terminal Server CN2600 series may get configuration changes from multiple hosts, the most recent command received will take precedence.

What is redundantComAllowDriverControl?

Controls whether Redundant COM driver control commands from connected hosts are honored when max connection is greater than 1; set to yes(1) to accept them, with the most recently received command taking precedence.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.3
snmpwalk -v2c -c public <target> MOXA-CN2600-MIB::redundantComAllowDriverControl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.3.1
snmpget -v2c -c public <target> MOXA-CN2600-MIB::redundantComAllowDriverControl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.3.1 i <value>

Start monitoring Moxa CN2600 serial device/terminal server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-CN2600-MIB::redundantComAllowDriverControl OID value, configure state conditions and alerts, and monitor any Moxa CN2600 serial device/terminal server from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2nportMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11cn2600MOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1swMgmtMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4portSettingMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1opModeSettingMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2applicationMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3redundantComMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1redundantComTableMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1redundantComEntryMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.4.1.2.3.1.1.3redundantComAllowDriverControlMOXA-CN2600-MIB