MOXA-CN2600-MIB :: power1Status

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-CN2600-MIB › power1Status

power1Status

Module: MOXA-CN2600-MIB

OID (symbolic): MOXA-CN2600-MIB::power1Status

OID (numeric): 1.3.6.1.4.1.8691.2.11.1.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The on/off status of power 1

What is power1Status?

Indicates whether power input 1 is currently on or off (power-off(0), power-on(1)). Since the CN2600 can run on dual power feeds, admins poll this to detect loss of the primary supply before it causes a full outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.1.11
snmpwalk -v2c -c public <target> MOXA-CN2600-MIB::power1Status

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.2.11.1.1.11.1
snmpget -v2c -c public <target> MOXA-CN2600-MIB::power1Status.1

Start monitoring Moxa CN2600 serial device/terminal server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-CN2600-MIB::power1Status OID value, configure state conditions and alerts, and monitor any Moxa CN2600 serial device/terminal server from a single console.

How to Use in IPNetwork Monitor

Select a Moxa CN2600 serial device/terminal server as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type power1Status into the Find box to locate it in the OID tree, then select it and click OK. The on/off status of power 1. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'power-on', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2nportMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11cn2600MOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1swMgmtMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.1overviewMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2.11.1.1.11power1StatusMOXA-CN2600-MIB