LM-SENSORS-MIB :: lmTempSensorsValue

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LM-SENSORS-MIB › lmTempSensorsValue

lmTempSensorsValue

Module: LM-SENSORS-MIB

OID (symbolic): LM-SENSORS-MIB::lmTempSensorsValue

OID (numeric): 1.3.6.1.4.1.2021.13.16.2.1.3

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The temperature of this sensor in mC.

What is lmTempSensorsValue?

This read-only Gauge32 reports the sensor's temperature reading in millidegrees Celsius (mC). Admins poll this value to monitor for overheating and can alert if it crosses a safe operating threshold. For example, a value of 45000 represents 45.0 degrees Celsius, and a monitoring system might alert if this climbs above 80000 (80 C).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2021.13.16.2.1.3
snmpwalk -v2c -c public <target> LM-SENSORS-MIB::lmTempSensorsValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2021.13.16.2.1.3.1
snmpget -v2c -c public <target> LM-SENSORS-MIB::lmTempSensorsValue.1

Start monitoring Linux server/host with lm_sensors-compatible hardware sensors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LM-SENSORS-MIB::lmTempSensorsValue OID value, configure state conditions and alerts, and monitor any Linux server/host with lm_sensors-compatible hardware sensors from a single console.

How to Use in IPNetwork Monitor

Select a Linux server/host with lm_sensors-compatible hardware sensor as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type lmTempSensorsValue into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The temperature of this sensor in mC. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2021ucdavisUCD-SNMP-MIB
1.3.6.1.4.1.2021.13ucdExperimentalUCD-SNMP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2021.13.16lmSensorsLM-SENSORS-MIB
1.3.6.1.4.1.2021.13.16.2lmTempSensorsTableLM-SENSORS-MIB
1.3.6.1.4.1.2021.13.16.2.1lmTempSensorsEntryLM-SENSORS-MIB
1.3.6.1.4.1.2021.13.16.2.1.3lmTempSensorsValueLM-SENSORS-MIB