HUAWEI-VLAN-MIB :: hwVmacIPoESubStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-VLAN-MIB › hwVmacIPoESubStatus

hwVmacIPoESubStatus

Module: HUAWEI-VLAN-MIB

OID (symbolic): HUAWEI-VLAN-MIB::hwVmacIPoESubStatus

OID (numeric): 1.3.6.1.4.1.2011.5.6.1.25.1.27

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Indicates the VLAN-based IPoE VMAC function. Options: 1. enable(1) -indicates that the IPoE VMAC function is enabled. 2. disable(2) -indicates that the IPoE VMAC function is disabled. 3. notConfig(3) -indicate by VLAN single switch. This leaf is optional for creating a VLAN service profile. The VLAN-based IPoE VMAC function can be configured in hwIpDslamL2pVlanCtrlVmacIPoESubStatus of HUAWEI-IPDSLAM-L2PPORTCONFIG-MIB. The status of the IPoE VMAC function is determined by its VLAN-level switch. The IPoE VMAC function of a VLAN is enabled only when the VLAN-level switch is enabled. If a VLAN service profile is bound to the VLAN, the configuration of the VLAN-based IPoE VMAC function in the VLAN service profile takes effect.

What is hwVmacIPoESubStatus?

Enables, disables, or defers the VMAC feature specifically for IPoE subscribers on VLANs bound to this profile, distinct from hwVmacStatus in that it's governed only by the VLAN-level switch with no separate global gate.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.5.6.1.25.1.27
snmpwalk -v2c -c public <target> HUAWEI-VLAN-MIB::hwVmacIPoESubStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.5.6.1.25.1.27.1
snmpget -v2c -c public <target> HUAWEI-VLAN-MIB::hwVmacIPoESubStatus.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2011.5.6.1.25.1.27.1 i <value>

Start monitoring Huawei enterprise/campus switch (VLAN configuration, e.g. CloudEngine S5735-L-V2) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-VLAN-MIB::hwVmacIPoESubStatus OID value, configure state conditions and alerts, and monitor any Huawei enterprise/campus switch (VLAN configuration, e.g. CloudEngine S5735-L-V2) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.5huaweiMgmtHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.5.6hwVlanHUAWEI-MIB
1.3.6.1.4.1.2011.5.6.1hwVlanMngObjectHUAWEI-VLAN-IF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.5.6.1.25hwVlanSrvProfTableHUAWEI-VLAN-MIB
1.3.6.1.4.1.2011.5.6.1.25.1hwVlanSrvProfEntryHUAWEI-VLAN-MIB
1.3.6.1.4.1.2011.5.6.1.25.1.27hwVmacIPoESubStatusHUAWEI-VLAN-MIB