HP-MCSG :: hpmcSGPkgSvcRestartCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HP-MCSG › hpmcSGPkgSvcRestartCount

hpmcSGPkgSvcRestartCount

Module: HP-MCSG

OID (symbolic): HP-MCSG::hpmcSGPkgSvcRestartCount

OID (numeric): 1.3.6.1.4.1.11.2.3.1.6.3.1.1.4.4.1.7

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The current number of times this service has been restarted.

What is hpmcSGPkgSvcRestartCount?

Running count of how many times this service has actually been restarted since it was last (re)started.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.1.6.3.1.1.4.4.1.7
snmpwalk -v2c -c public <target> HP-MCSG::hpmcSGPkgSvcRestartCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.1.6.3.1.1.4.4.1.7.1
snmpget -v2c -c public <target> HP-MCSG::hpmcSGPkgSvcRestartCount.1

Start monitoring HP-UX server running ServiceGuard cluster software with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-MCSG::hpmcSGPkgSvcRestartCount OID value, configure state conditions and alerts, and monitor any HP-UX server running ServiceGuard cluster software from a single console.

How to Use in IPNetwork Monitor

Select an HP-UX server running ServiceGuard cluster software as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpmcSGPkgSvcRestartCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The current number of times this service has been restarted. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.1generalHP-EMS
1.3.6.1.4.1.11.2.3.1.6hpmcClusterHP-MCCLUSTER
1.3.6.1.4.1.11.2.3.1.6.3hpmcTypeSpecificHP-MCCLUSTER
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.1.6.3.1hpmcSGClusterHP-MCSG
1.3.6.1.4.1.11.2.3.1.6.3.1.1hpmcSGObjectsHP-MCSG
1.3.6.1.4.1.11.2.3.1.6.3.1.1.4hpmcSGPkgInfoHP-MCSG
1.3.6.1.4.1.11.2.3.1.6.3.1.1.4.4hpmcSGPkgSvcTableHP-MCSG
1.3.6.1.4.1.11.2.3.1.6.3.1.1.4.4.1hpmcSGPkgSvcEntryHP-MCSG
1.3.6.1.4.1.11.2.3.1.6.3.1.1.4.4.1.7hpmcSGPkgSvcRestartCountHP-MCSG