HP-MCCLUSTER :: hpmcClusterUpTime

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HP-MCCLUSTER › hpmcClusterUpTime

hpmcClusterUpTime

Module: HP-MCCLUSTER

OID (symbolic): HP-MCCLUSTER::hpmcClusterUpTime

OID (numeric): 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: The time (in hundredths of a second) since this instance of the cluster was last started. Dynamic reconfiguration or partial availability of the cluster does not reset the cluster uptime. A value of 0 indicates that the time is unknown by this node.

What is hpmcClusterUpTime?

A TimeTicks value, in hundredths of a second, reporting how long this cluster instance has been running since it was last started. Because dynamic reconfiguration doesn't reset this counter, admins can use it to confirm cluster continuity across node adds and removes rather than mistaking a reconfig for a full restart. A cluster showing an uptime of over 200 days despite several node failovers tells an admin the cluster itself has remained continuously available even though individual members changed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13
snmpwalk -v2c -c public <target> HP-MCCLUSTER::hpmcClusterUpTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13.1
snmpget -v2c -c public <target> HP-MCCLUSTER::hpmcClusterUpTime.1

Start monitoring HP server clusters with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-MCCLUSTER::hpmcClusterUpTime OID value, configure state conditions and alerts, and monitor any HP server clusters from a single console.

How to Use in IPNetwork Monitor

Select an HP server cluster as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpmcClusterUpTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The time (in hundredths of a second) since this instance of the cluster was last started. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.1generalHP-EMS
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.1.6hpmcClusterHP-MCCLUSTER
1.3.6.1.4.1.11.2.3.1.6.1hpmcClusterObjectsHP-MCCLUSTER
1.3.6.1.4.1.11.2.3.1.6.1.1hpmcGenInfoHP-MCCLUSTER
1.3.6.1.4.1.11.2.3.1.6.1.1.2hpmcClusterTableHP-MCCLUSTER
1.3.6.1.4.1.11.2.3.1.6.1.1.2.1hpmcClusterEntryHP-MCCLUSTER
1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13hpmcClusterUpTimeHP-MCCLUSTER