All MIBs › HP-MCCLUSTER › hpmcClusterUpTime
hpmcClusterUpTime
Module: HP-MCCLUSTER
OID (symbolic): HP-MCCLUSTER::hpmcClusterUpTime
OID (numeric): 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13
Node type: OBJECT-TYPE
Type: TimeTicks
Access: read-only
Description: The time (in hundredths of a second) since this instance of the cluster was last started. Dynamic reconfiguration or partial availability of the cluster does not reset the cluster uptime. A value of 0 indicates that the time is unknown by this node.
What is hpmcClusterUpTime?
A TimeTicks value, in hundredths of a second, reporting how long this cluster instance has been running since it was last started. Because dynamic reconfiguration doesn't reset this counter, admins can use it to confirm cluster continuity across node adds and removes rather than mistaking a reconfig for a full restart. A cluster showing an uptime of over 200 days despite several node failovers tells an admin the cluster itself has remained continuously available even though individual members changed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13 snmpwalk -v2c -c public <target> HP-MCCLUSTER::hpmcClusterUpTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13.1 snmpget -v2c -c public <target> HP-MCCLUSTER::hpmcClusterUpTime.1
Start monitoring HP server clusters with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-MCCLUSTER::hpmcClusterUpTime OID value, configure state conditions and alerts, and monitor any HP server clusters from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3 | hpsystem | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.1 | general | HP-EMS |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.3.1.6 | hpmcCluster | HP-MCCLUSTER |
| 1.3.6.1.4.1.11.2.3.1.6.1 | hpmcClusterObjects | HP-MCCLUSTER |
| 1.3.6.1.4.1.11.2.3.1.6.1.1 | hpmcGenInfo | HP-MCCLUSTER |
| 1.3.6.1.4.1.11.2.3.1.6.1.1.2 | hpmcClusterTable | HP-MCCLUSTER |
| 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1 | hpmcClusterEntry | HP-MCCLUSTER |
| 1.3.6.1.4.1.11.2.3.1.6.1.1.2.1.13 | hpmcClusterUpTime | HP-MCCLUSTER |