GPON-MIB :: recFrames

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › GPON-MIB › recFrames

recFrames

Module: GPON-MIB

OID (symbolic): GPON-MIB::recFrames

OID (numeric): 1.3.6.1.4.1.13464.1.11.4.9.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Received frames

What is recFrames?

This is a cumulative counter of the total number of Ethernet frames this ONT port has received from the subscriber's connected equipment. An administrator uses it as a basic traffic-volume indicator, watching for it to stop incrementing as a sign the port has gone quiet. Like all the counters in this table, it wraps back to 0 after reaching its 32-bit maximum.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.13464.1.11.4.9.1.1
snmpwalk -v2c -c public <target> GPON-MIB::recFrames

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.13464.1.11.4.9.1.1.1
snmpget -v2c -c public <target> GPON-MIB::recFrames.1

Start monitoring Zyxel Systems GPON OLT (optical line terminal) equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GPON-MIB::recFrames OID value, configure state conditions and alerts, and monitor any Zyxel Systems GPON OLT (optical line terminal) equipment from a single console.

How to Use in IPNetwork Monitor

Select a Zyxel Systems GPON OLT (optical line terminal) equipment as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type recFrames into the Find box to locate it in the OID tree, then select it and click OK. It reports the received frames. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.13464adminADMIN-MASTER-MIB
1.3.6.1.4.1.13464.1dataComADMIN-MASTER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.13464.1.11gponGPON-MIB
1.3.6.1.4.1.13464.1.11.4ontGPON-MIB
1.3.6.1.4.1.13464.1.11.4.9ontEthStaTableGPON-MIB
1.3.6.1.4.1.13464.1.11.4.9.1ontEthStaEntryGPON-MIB
1.3.6.1.4.1.13464.1.11.4.9.1.1recFramesGPON-MIB