All MIBs › G6-SCRIPTDATA-MIB › parameterValue
parameterValue
Module: G6-SCRIPTDATA-MIB
OID (symbolic): G6-SCRIPTDATA-MIB::parameterValue
OID (numeric): 1.3.6.1.4.1.3181.10.6.3.77.1.1.3
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: Customer entered parameter value. This may be a string or a number depending of the script requirement.
What is parameterValue?
This object holds the actual value a customer or administrator enters for a named script parameter, which may represent either a text string or a numeric value depending on what the specific script expects. An administrator sets this to feed configuration input into an onboard automation script, such as a threshold number or a device label the script uses in its logic. Setting parameterValue to "300" for a parameter the script treats as a timeout, for example, would configure that script's behavior accordingly.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.3.77.1.1.3 snmpwalk -v2c -c public <target> G6-SCRIPTDATA-MIB::parameterValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.3.77.1.1.3.1 snmpget -v2c -c public <target> G6-SCRIPTDATA-MIB::parameterValue.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.3.77.1.1.3.1 s <value>
Start monitoring MICROSENS Generation 6 (G6) managed Ethernet switch (onboard scripting engine data store) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-SCRIPTDATA-MIB::parameterValue OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 (G6) managed Ethernet switch (onboard scripting engine data store) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3181 | microsens | MICROSENS-G6-MIB |
| 1.3.6.1.4.1.3181.10 | managedSwitches | MICROSENS-G6-MIB |
| 1.3.6.1.4.1.3181.10.6 | g6 | MICROSENS-G6-MIB |
| 1.3.6.1.4.1.3181.10.6.3 | management | G6-ACCESS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3181.10.6.3.77 | scriptdata | G6-SCRIPTDATA-MIB |
| 1.3.6.1.4.1.3181.10.6.3.77.1 | parameterTable | G6-SCRIPTDATA-MIB |
| 1.3.6.1.4.1.3181.10.6.3.77.1.1 | parameterEntry | G6-SCRIPTDATA-MIB |
| 1.3.6.1.4.1.3181.10.6.3.77.1.1.3 | parameterValue | G6-SCRIPTDATA-MIB |