Fore-TC-MIB :: foreTcTotalLcdSeconds

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-TC-MIB › foreTcTotalLcdSeconds

foreTcTotalLcdSeconds

Module: Fore-TC-MIB

OID (symbolic): Fore-TC-MIB::foreTcTotalLcdSeconds

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.12.2.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of seconds in which the LCD (loss of cell delineation) defect occured. An LCD defect is detected when an out of cell delineation state has persisted for 4ms. The defect is cleared when sync state has been maintained for 4ms.

What is foreTcTotalLcdSeconds?

Cumulative count of seconds during which the interface was in a Loss of Cell Delineation (LCD) defect state, declared after 4ms out of sync and cleared after 4ms back in sync. Rising values point to an unstable or noisy ATM physical link.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.12.2.1.1
snmpwalk -v2c -c public <target> Fore-TC-MIB::foreTcTotalLcdSeconds

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.12.2.1.1.1
snmpget -v2c -c public <target> Fore-TC-MIB::foreTcTotalLcdSeconds.1

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch (ATM traffic convergence layer/textual conventions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-TC-MIB::foreTcTotalLcdSeconds OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch (ATM traffic convergence layer/textual conventions) from a single console.

How to Use in IPNetwork Monitor

Select a Fore Systems (later Marconi) ForeRunner ATM switch (ATM traffic convergence layer/textual conventions) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type foreTcTotalLcdSeconds into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of seconds in which the LCD (loss of cell delineation) defect occured. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.12foreTcMibFore-TC-MIB
1.3.6.1.4.1.326.2.2.1.1.12.2foreTcTotalTableFore-TC-MIB
1.3.6.1.4.1.326.2.2.1.1.12.2.1foreTcTotalEntryFore-TC-MIB
1.3.6.1.4.1.326.2.2.1.1.12.2.1.1foreTcTotalLcdSecondsFore-TC-MIB