Fore-SONET-MIB :: sonetSectionBIPs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFore-SONET-MIBsonetSectionBIPs

sonetSectionBIPs

Module: Fore-SONET-MIB

OID (symbolic): Fore-SONET-MIB::sonetSectionBIPs

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.4.2.1.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of Section BIP-8 (Bit Interleaved Parity) errors that have been detected since the last time the port has been reset. The calculated BIP-8 code is compared with the BIP-8 code extracted from the B1 byte of the following frame. Differences indicate that a section level bit error has occurred.

What is sonetSectionBIPs?

Counts Section BIP-8 parity errors detected on this port since its last reset, found by comparing the calculated BIP-8 code against the B1 byte of the following frame. An admin watches this counter for steady increases as a sign of section-layer signal quality problems, e.g. a marginal fiber connection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.2.1.1.4
snmpwalk -v2c -c public <target> Fore-SONET-MIB::sonetSectionBIPs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.2.1.1.4.1
snmpget -v2c -c public <target> Fore-SONET-MIB::sonetSectionBIPs.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sonetSectionBIPs.1

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-SONET-MIB::sonetSectionBIPs OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules from a single console.

How to Use in IPNetwork Monitor

Select a Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port module as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sonetSectionBIPs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of Section BIP-8 (Bit Interleaved Parity) errors that have been detected since the last time the port has been reset. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326marconiES1000-MIB
1.3.6.1.4.1.326.2systemsES1000-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.4foreSonetModuleFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.2sonetStatsGroupFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.2.1sonetSectionTableFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.2.1.1sonetSectionEntryFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.2.1.1.4sonetSectionBIPsFore-SONET-MIB